High Flow Series Filter Cartridges - Engineered Filtration, Inc.
Product Categories

Products Details

High Flow Series Filter Cartridges

Large Geometry Pleated Filters for High Flow

The High Flow Series filters feature a larger geometry to handle high-flows with fewer filter elements. The result is much faster, easier filter changeouts. In addition, the inside to outside flow allows for excellent dirt holding capacity, extending the time between filter changeouts. Filter housings are also available and because of the filter’s high flow and dirt holding capacity, smaller systems are possible, reducing upfront capital costs.

Product Specifications

  • Media/Support/Cage: Polypropylene
  • End Caps: Polypropylene
  • Gaskets/O-Rings: Buna-N, EPDM, Silicone, Viton
  • Micron rating: 1, 3, 5, 10, 20, 40, 60, 75, 100 µm

Dimensions

Nominal lengths:
  • 20″, 40″, 60″
  • 508, 1016, 1524 cm
Outside diameter: 6.0″ (15.2 cm)
Surface Area:
  • 24 ft² (2.2 m²) per 20″ element
  • 49 ft² (4.6 m²) per 40″ element
  • 73 ft² (6.8 m²) per 60″ element

TYPICAL APPLICATIONS

  • Water Systems
  • Chemicals
  • Food and Beverage
  • Pre RO

Operating Parameters

  • Maximum operating temperature: 176°F (80°C)
  • Maximum differential pressure:
    • 75 psid @ 72°F (5.2 bar @ 21°C)
    • 30 psid @ 176°F (2.0 bar @ 80°C)
  • Maximum reverse pressure:
    • 40 psid @ 72°F (2.8 bar @ 21°C)
  • Recommended change-out pressure:
    • 35 psid (2.4 bar)
  • Maximum flow rates:
    • 60″ element up to 500 GPM (1892 lpm)
    • 40″ element up to 350 GPM (1325 lpm)
    • 20″ element up to 175 GPM (662 lpm)

Flow rates for sizing assistance based on clean water.

FEATURES & BENEFITS

  • 6″ diameter, large geometry for high flow rates
  • Absolute retention ratings from 1 to 100 microns
  • Capable of flow rates up to 500 GPM in a single 60″ element
  • Inside-out flow retains contaminant even during changeout
  • Multi layer pleated construction with optimized surface area
  • Outer cage prevents media extrusion problem experienced with some competitive offerings
  • Unique Quad Seal gasket provides maximum seal integrity
  • Retrofits competitive high flow filter housings
  • Thermally bonded construction

CERTIFICATIONS

  • FDA Listed Materials: All materials comply with FDA Title 21 of the Code of Federal Regulations Sections 174.5 and 177.1520, as applicable for food and beverage contact.
  • European Directive for Direct Food Contact: European Regulation No. 1935/2004 and European Regulation 10/2011: Tested for migration behavior and is suitable for contact with all kinds of foodstuffs with minimal rinse-up. Data available upon request.
  • NSF 61: Certified to NSF/ANSI STD 61 for materials requirements only — Component.

Filter Housings for High Flow Applications

The High Flow Series filter housings are designed to accept and competitive High Flow Series large geometry filter elements. Available in both vertical and horizontal orientations, the High Flow housings can accept from 1 to 7 filter elements. Also available is a single round tipped horizontal design that allows easier removal without the need for a platform and readily drains from back of vessel to eliminate fluid spills.

Product Specifications

Shell/O-Ring:
Buna-N, EPDM, Silicone, Viton
Optional:
300 psig (20.6 bar) Flanged Head designs available – Consult Factory Not for use with compressed gases

Operating Parameters

Maximum operating pressure:
Carbon Steel 150 psig (10.3 bar) @ 500°F (260°C) in liquid service Stainless Steel 150 psig (10.3 bar) @ 300°F (149°C) in liquid service Not for use with compressed gases

Available Options

  • Vertical Housing Inlet/Outlet Side in/Side out
  • Vertical Housing Inlet/Outlet Side in/Bottom out
  • Horizontal Housing Inlet/Outlet Side in/Bottom out
  • Tilted Horizontal Side in/Side out
  • Tilted Horizontal Side in/Bottom out
  • Gauge ports
  • Hinged cover
  • Davit arm

FEATURES & BENEFITS

  • Industrial grade housings available in 304, 316 and carbon steel wetted parts
  • ASME U code available
  • Designs for 1, 3, 4 or 7 filters per housing for flows up to 3500 GPM*
  • 150 psig designs
  • Accepts 20″, 40″ and 60″ High Flow cartridges
  • Vertical and horizontal designs offered
  • Hold down plate prevents elements from unseating due to back pressure
  • Filter removal tool available to facilitate element changeout
  • Swing bolts on 150 psig design
  • Equipped with 1″ vent and 2″ drain
    (1″ drain on tipped horizontal style)

TYPICAL APPLICATIONS

  • Pre RO
  • Water
  • Desalination
  • Oil and Gas
  • Food and Beverage
  • Pulp and Paper
  • Petrochemicals

FLOW CAPACITY

Flow capacity based on light dirt load and low viscosity. Actual flow rate may be lower with vessel sizing based on dirt load, fluid dirt loads, nature of contaminant, viscosity, micron rating and temperature.
×